Perfectly equipped analytical laboratory allows us to check values of chemical baths several times a day. We can react very quickly and provide immediate addition of chemicals to the bath without any chances of production inquality. We regularly monitor not only the values in electroplating baths, but also the quality and thickness of the surfaces in individual operations.
measured variables | method | device type | manufacturer |
thickness of final finishes/composition of the solder | X-ray spektrophotometer | Fischerscope XDAL237 | Helmut Fischer |
metal contents in the bath | Atomic absorption spectrometer | AA-7000 | SHIMADZU |
The content of organic additives in electroplating baths | cyclic voltametry CVS | 797VA Computrace | METROHM |
cross-sections of PCB´s | metallurgical cross-section | Metallurgical Microscop |